70 Emphasis Console v2.0.0 User Manual
Edit Frame Table Values
Step 1: From an open Frame table press <S7 - More Softkeys> and then choose
between <S1 - Start Value>, <S2 - Center Value>, or <S3 - Ending Value>.
Step 2: Type the new DMX value for the respective field.
Step 3: Press [Enter]. The cursor will automatically jump from start value, to center
value, to end value. After the end value it will ask you to select another frame.
Note:
Frame Tables are not referenced data. When recorded, they are recorded as DMX values
only, not as frames. Therefore, changes to Frame Tables will not automatically update
any recorded data (i.e. cues, focus points) attributed to those tables. Any recorded data
associated with a changed Frame Table will need to be re-written to accomodate for the
changes made to the frame table.