Electronic Theatre Controls Emphasis Lighting Control System Manual do Utilizador Página 263

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 262
Maintenance and Troubleshooting 253
Installing Remote Focus Unit
A Remote Focus Unit (RFU) is used to select channels, set levels, record and playback
cues and playback macros. An RFU can be connected to the back of your Facepanel, or to
a Video Node or RFU-Enabled DMX Node, or to dedicated RFU connectors that may be
distributed throughout your venue.
Install the RFU:
Step 1: Verify that RFU power switch is turned Off. (Unit is off when switch is in the
position toward the bottom edge of the RFU.)
Step 2: Insert the RFU cable into the connector on the back of the facepanel labeled
RFU. RFUs may also be connected to ETCNet2 Nodes.
Step 3: Turn RFU power switch to On.
RFU pinout for XLR 6-pin female
1 Data (+) (to RFU)
2Data ()
3 Data (+) (from RFU)
4Data ()
5 Common (AC ground)
6 +12 Vdc (fused, 2 amp)
Push
1
2
3
4
5
6