5 Blind Editing 137
Blocked Channels
In some cases, you may want to be able to stop a [Track] record for a specific channel or
channels, but you may not want to create a block cue. To accomplish this, you can place a
block instruction on a channel and record it into a cue.
Place a channel block:
Step 1: Press [Blind]. The Blind display defaults to cues.
Step 2: Press [x] [Enter] to select cue [x]. You can also use the [+] and [-] keys to
increment and decrement through the cue list.
Step 3: Select channels using the procedure described in Select Channels, Dimmers
and Fixtures, page 86.
Step 4: Press <S7 - More Softkeys> [S6 - Block].
Step 5: Press [1] [Enter] to set a block on selected channels. Blocked channels’ levels
will be displayed in white. Alternatively, press [0] [Enter] to clear a block from
selected channels.
Cue List
In the Cue List display, you can view and edit the cue numbers and their attributes. You can
edit one or a number of cues at a time, using the arrow keys to navigate within the list.
Edit cue attributes within the cue list display:
Step 1: Press [Blind]. The Blind display defaults to cues.
Step 2: Press [S2 - Cue List] to display the cue list.
Step 3: Press [x] [Enter] to select cue [x]. You can also use [And], [Thru] and [Except]
to select multiple cues. You may also use the up- and down arrow ([
v] and [u])
keys to scroll through the cue list.
Step 4: If necessary, press [Part] [y] to select part [y] of cue [x]. Only timing functions
can be edited for cue parts. To add a link, follow time and/or rate to a part cue,
select the whole cue number.
Step 5: Press:
[Type] to change the cue type for the selected cue(s). See Cue Types, page
112.