Maintenance and Troubleshooting 259
Expression/Insight facepanels
There are three typical ways to wire the Remote Macros:
#1: Connect all -Macro pins (pins 1-8) to ground (pin 10) and switch the leads connecting
the +Macro pins (pins 14-21) to +12 Vdc (pin 24) as shown in the following diagram.
#2: Connect all +Macro pins (pins 14-21) to +12 Vdc (pin 24) and switch the leads
connecting the -Macro pins (pins 1-8) to ground (pin10).
#3: Provide your own power supply that generates a 12 Vdc potential between the +Macro
and -Macro pins and switch either of these leads.
Note:
The macro numbers in these examples are the defaults, and may not correspond to the
macros you are using.
Ground
Ground
+12 Vdc
+12 Vdc
not connected
not connected
not connected
not connected
not connected
+Macro 1901
+Macro 1902
+Macro 1903
+Macro 1904
+Macro 1905
+Macro 1906
+Macro 1907
+Macro 1908
-Macro 1901
-Macro 1902
-Macro 1903
-Macro 1904
-Macro 1905
-Macro 1
906
-Macro 1907
-Macro 1908
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25