40 Ion Operations Manual
Spreadsheet (Blind Only)
Spreadsheet format is available only in blind mode. It is useful for viewing channel data and data
trends for multiple cues, submasters, palettes, or presets at one time. Cues and other record
targets are displayed on the vertical axis and channel or parameter data is visible on the horizontal
axis.
Since this is a blind-only view, changes made in this view are immediate and do not require a record
or update.
As with table view, spreadsheet format allows you to choose exactly which parameters you want to
view. Parameters can be expanded/suppressed by holding [Data] and pressing the desired
parameter buttons in the CIA. Category data is not available in spreadsheet, but you may hide all
parameters of a specific category by holding [Data] and pressing the desired category button to the
right of the LCD.