252 Ion Operations Manual
Set
The “Set” command allows MSC to control potentiometers using both a numeric control number
(which specifies the potentiometer) and a data field (which controls the level: 0-100). Control values
are as follows:
Accompanying any of these indications in the MSC data, a numeric value of 0-100 would set the
specified potentiometer to that level.
All other control values are ignored.
Fire
This command fires a macro. MSC supports macros 1 through 127 only. Therefore a numeric value
of 1 - 127 would accompany this command.
Control
Value
Indication
1-127 Submaster 1-127
128 Primary playback in
129 Primary playback out
510 Grandmaster
Vista de página 265