Express 125/250 User Manual, v.3.1 327
RVI ETCNet DIP switch settings
In order to enable the RVI for use on the ETCNet network, you must verify
or adjust the settings of two sets of DIP switches. You will need to use a
pin or a similar fine-pointed object to set the switches.
To set the switches, follow these steps.
1. Locate the two sets of DIP switches, visible through the right side
panel of the RVI. See the drawing below.
2. Set all six switches of the DIP closest to the front of the RVI to the Off
position (up). Set all six switches of the DIP closest to the back of the
RVI to the On position (down).
125
Installing remote video monitors
You can have additional monitors at remote locations. Connect them to
RIUs or RVIs operating on ETCNet. These remote monitors duplicate the
console’s displays.
Connect monitors to interface devices by following these steps.
1. Insert the female end of the monitor power cord in the monitor
connector, and the male end of the monitor power cord in the
interface device connector labeled Switched outlets.
2. Connect the cable to the connector labeled CRT 1.
3. Turn monitor power switch to its On position.
VGA monitor console connector
HD-DB15 female
VGA monitor pinout
1 Red video
2 Green video
3Blue video
4Ground
5Ground
6 Red ground
7 Green ground
8 Blue ground
9 not connected
10 Ground
11 Ground
12 not connected
13 Horizontal (H/V) sync
14 Vertical sync
15 not connected
125.
If using an older console and thinnet wiring, please see Using thinnet with older
consoles, page 328, for different DIP switch settings.