308 Appendix A Installation
Console’s back panel
External device fuse
If you have an external device such as console lights, an RFU or a remote
macro controller connected to the console and it doesn’t operate, check
the External 12V fuse. This fuse is located in a pop-out receptacle located
next to the RFU port.
1. Turn off the console.
2. Remove the power cord.
3. Remove the cover of the fuse receptacle with a flat blade screwdriver.
4. Remove and examine the fuse. Telltale signs of a blown fuse include
discoloration or deposits on the glass envelope and/or a visibly broken
fuse strip.
5. If you find a blown fuse, replace it with the fuse of the same size and
type.
6. With a good fuse installed, reinsert the fuse into the rear panel holder
and secure with the screwdriver.
7. Verify that the external device works properly. If still having problems,
see Help from ETC Technical Services, page 11, to get help from ETC.