7
J. Physical
1. All operator controls and console electronics for a standard system shall be housed in a
single desktop console, not to exceed 19” wide, 19” deep, 5.5” high, weighing 20 pounds. Consoles
that will not fit in a 19" rack shall not be acceptable.
2. Console power shall be 95 – 240V AC at 50 or 60Hz, supplied via a detachable power cord.
END OF SECTION
SCHEDULE OF QUANTITIES
Dimmer Rack SR3-48 1
Control Module CEM3 1
Dimmer Modules D20 48
Dimmer Rack DRd12 1
Processor P-ACP 1
Dimmer Modules D20 8
Air Flow Modules AFM 4
Dimmer Bar SB6 4
Control Equipment Rack RACK 1
Control Rack Equipment RACK 1
Control Console LMNT-60-500 1
Monitor MON 1
Worklight WRKLGT 1
Data Device N31G-1F 1
Plug In Stations ECPB Uni/Net 3
ECPB Net 5
Architectural Controls P-LCD-P 1
UH10005 4
Floor Pocket Insert 850X-B 4
ALTERNATE BID EQUIPMENT
Connector Strips 9950 4
Control console ION-60-10,000 1
Monitor MON 2