2. Non-intensity parameters may be set numerically or via the on demand moving
light controls. This control shall be fully interactive. In either case the current
parameter value shall be displayed on the console monitor.
3. Only those parameters available for control in the active lighting system shall
be displayed for control.
4. Lamp controls provide direct access to luminaire functions such as striking and
dousing arc lamps and calibrating entire fixtures or individual mechanisms of
fixtures, as provided by the luminaire manufacturer. User access to these
features is normalized across all manufacturers for ease of use. Use of a
“control channel” for accessing these functions shall not be required and
systems requiring use of a control channel shall not be acceptable.
5. Fixtures with CMY or RBG color mixing may be set with direct CMY or RBG
controls, as well as the Hue and Saturation controls and/or color picker. Color
may also be set directly to a gel match, normalized to 3200K.
(2) Playback Section
1. The master fader shall consist of a 60mm Master Fader pair with associated
Load, Go and Stop/Back buttons.
2. It shall be possible to instantaneously halt an active cue, go back to the
previous cue, manually override the intensity fade or manually override the
entire fade.
(3) Integral Channel/Submaster Faders
1. Submaster and fader support shall be provided via 40 or 60 integral 45mm
faders with bump leys. These faders shall be pageable and shall operate in
LTP channel and LTP/HTP submaster modes.
2. LTP channel mode shall allow the user access to intensity of the first 120
channels and shall operate with LTP logic. Faders that are not currently set to
the same level as the corresponding channel shall have to be matched to that
level before affecting said channel.
3. Up to 240 proportional, fully overlapping additive or inhibitive submasters may
be defined. Submasters shall have colored LEDs to indicate submaster status.
Each submaster may have fade up, dwell and down fade times. Each has a
bump and assert/channel select button. Submasters may be set to
independent, exclusive and proportional/intensity master control.
4. The submaster blind buffer shall be linked directly to live playback allowing live
editing of live submaster content via the command line.
5. It shall be possible to set submaster values directly from the command line.
(4) Grand Master
1. A dedicated 60mm grand master and blackout button are provided.
2. The grand master shall proportionally fade intensity values to zero. Blackout
shall send all intensity outputs to zero. Non-intensity outputs shall not be
affected. No additional configuration shall be required to withhold non-intensity
values from Grand Master and Blackout control.