8
between 32ºF (0ºC) and 104ºF (40C), and humidity between 10 - 90% (non-
condensing).
2) Optimum cooling shall be when the units are mounted horizontally with the control
panel vertical (or upright).
2) CONTROL EQUIPMENT RACK
A) General
1) The control equipment rack shall be a standard 19” equipment rack, such as
manufactured by Middle Atlantic Products and based on the EWR style with separate
wiring backpan. This rack shall house the control equipment necessary to complete the
system functions and configuration.
2) The equipment housed in the control equipment rack shall be, but is not limited to, the
network switch, the network patch, any network conversion device, any data
distribution device and any data conversion device that is necessary for the function
and completion of the system as a whole.
3) The specific equipment required is to be notated and shown on the drawings and
contained in the schedule of quantities.
3) LIGHTING CONSOLE AND ACCESSORIES
A) General
(1) The lighting control console shall be a microprocessor-based system specifically
designed to provide complete control of stage, studio, and entertainment lighting
systems. The console shall be the Element as manufactured by Electronic Theatre
Controls, Inc., or equal.
(2) The control system shall be Net3 and ETCNet2 native, with both protocols output
simultaneously over the network. The system shall also be able to control third party
ACN devices directly. The system shall provide control of 1024 outputs on 250 or 500
channels.
(3) A maximum of 10,000 cues, 1000 groups, 1000 Intensity Palettes, 1000 Color
Palettes, 1000 Focus Palettes, 1000 Beam Palettes, 1000 effects, 1000 macros and
100 curves may be contained in non-volatile electronic memory and stored to an
onboard hard disk or to any USB storage device.
(4) The console may be placed in Tracking or Cue Only mode by the user as a system
default and overridden on individual record actions as required.
(5) A Master Playback fader pair and dedicated Grand Master/Blackout shall be provided.
(6) The console shall provide 40 or 60 pageable faders and bump keys that may be
operated in either LTP channel or HTP/LTP submaster mode. The console shall
support a total of 300 submasters.
(7) A high-resolution level wheel shall be provided to control intensity for selected
channels and scrolling within selected displays. On demand moving light controls shall
be provided for control of other non-intensity parameters. Non-intensity parameters
shall be controllable via the on demand or keypad controls.