4
6. MIDI/SMPTE Gateways
7. I/O Gateway with 12 analog inputs, 12 SPDT contact outputs, RD232
interface
8. Element Client Software Kit
C) Physical
(1) All operator controls and console electronics for a standard system shall be housed in
a single desktop console, not to exceed 32.9” wide, 17.9” deep, 5.1” high, weighing 30
pounds.
(2) Console power shall be 95 – 240V AC at 50 or 60Hz, supplied via a detachable power
cord.
D) DMX ETHERNET GATEWAY – ONE PORT
(a) General
(1) The lighting control gateway shall be a microprocessor-based unit specifically
designed to provide DMX-512 control of lighting. The gateway shall permit DMX-512
data to be encoded, routed over an Ethernet network and decoded back to DMX-512.
The unit shall be a Net3 DMX 1-port Gateway as provided by ETC, Inc.
(2) Gateways shall communicate over Ethernet directly with at least ETC, Inc.’s
entertainment and architectural lighting control products and other Ethernet interfaces.
(3) Connections shall be made between gateways, consoles, architectural systems, and
PCs over standard Ethernet distribution systems using 10/100BaseT.The gateway
shall support multiple protocols including:
(a) ANSI E1.31 Streaming ACN (sACN)
(b) ANSI E1.11 USITT DMX512-A
(c) ETCNet2 protocol suite
(d) ETCNet protocol suite
(4) The gateway shall be tested to UL standards and labeled ETL Listed.
(5) The gateway shall be RoHS Compliant (lead-free).
(6) The gateway shall be CE compliant.
(7) The gateway shall be configurable using Network Configuration Editor (NCE) software.
(8) Each gateway shall have power and network activity LEDs
B) DMX Ports
(1) DMX Port shall comply with the requirements of ANSI E1.11 USITT DMX512-A
standards.
(2) The DMX port shall be software-configurable for either input or output functionality.
(3) Hardware configuration override setting shall be provided on the gateway.
(4) DMX input shall be optically-isolated from the gateway electronics.
(5) DMX output shall be earth-ground referenced.
(6) DMX Port shall be capable of withstanding fault voltages of up to 250vAC without
damage.
(7) Each port shall incorporate one DMX512-A Connection
(a) Each DMX port location shall support a single 5-pin male XLR or 5-pin female XLR
(8) Network gateways that do not indicate input/ output port configuration or presence of
valid data shall not be accepted